{"id":751,"date":"2026-10-21T08:20:36","date_gmt":"2026-10-21T08:20:36","guid":{"rendered":"https:\/\/meshcom.pl\/?page_id=751"},"modified":"2026-10-22T05:26:59","modified_gmt":"2026-10-22T05:26:59","slug":"751-2","status":"publish","type":"page","link":"https:\/\/meshcom.pl\/?page_id=751","title":{"rendered":"WX i telemetria w MeshCom 4.0"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-transparent ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#1_Jak_dziala_telemetria\" >1. Jak dzia\u0142a telemetria<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#2_Obslugiwane_czujniki\" >2. Obs\u0142ugiwane czujniki<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#3_Podlaczenie_czujnikow\" >3. Pod\u0142\u0105czenie czujnik\u00f3w<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#BMEBMP280\" >BME\/BMP280<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#1-Wire_DS18B20_DHT11\" >1-Wire (DS18B20, DHT11)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#4_Odczyt_danych\" >4. Odczyt danych<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#5_Stale_grupy_pomiarowe_APRSfi\" >5. Sta\u0142e grupy pomiarowe (APRS.fi)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#6_Wlasna_grupa_pomiarowa\" >6. W\u0142asna grupa pomiarowa<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#Jak_to_dziala\" >Jak to dzia\u0142a<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#Ustawienie_z_wiersza_polecen\" >Ustawienie z wiersza polece\u0144<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#7_Mapy_klienci_i_projekty_spolecznosci\" >7. Mapy, klienci i projekty spo\u0142eczno\u015bci<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/meshcom.pl\/?page_id=751\/#Zrodla\" >\u0179r\u00f3d\u0142a<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"1_Jak_dziala_telemetria\"><\/span>1. Jak dzia\u0142a telemetria<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>W\u0119ze\u0142 MeshCom z pod\u0142\u0105czonym czujnikiem wysy\u0142a dane pomiarowe jako osobny rodzaj wiadomo\u015bci (telemetria) na cz\u0119stotliwo\u015bci MeshCom, domy\u015blnie 433,175 MHz. Gdy dane dotr\u0105 do serwera MeshCom, s\u0105 przekazywane do dashboardu APRS.fi w formacie telemetrii APRS.<\/p>\n<p>Dane pogodowe s\u0105 te\u017c wysy\u0142ane razem z pozycj\u0105 w\u0119z\u0142a (co 30 minut), je\u015bli czujnik jest pod\u0142\u0105czony. Szczeg\u00f3\u0142y: <a href=\"https:\/\/meshcom.pl\/?page_id=687\">Wysy\u0142anie pozycji<\/a>.<\/p>\n<p><strong>Aplikacja na telefon nie jest potrzebna do samego nadawania.<\/strong> W\u0119ze\u0142 z czujnikiem wysy\u0142a dane samodzielnie. Aplikacja i konsola s\u0142u\u017c\u0105 do ustawienia czujnik\u00f3w i podgl\u0105du warto\u015bci.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"2_Obslugiwane_czujniki\"><\/span>2. Obs\u0142ugiwane czujniki<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Czujnik<\/th>\n<th>Co mierzy<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>BMP\/BME280<\/td>\n<td>ci\u015bnienie, wilgotno\u015b\u0107, temperatura (I2C, adres 0x77)<\/td>\n<\/tr>\n<tr>\n<td>BMP390<\/td>\n<td>ci\u015bnienie<\/td>\n<\/tr>\n<tr>\n<td>BME680<\/td>\n<td>ci\u015bnienie, temperatura, wilgotno\u015b\u0107, jako\u015b\u0107 powietrza (rezystancja gazu)<\/td>\n<\/tr>\n<tr>\n<td>DS18B20, DHT11<\/td>\n<td>temperatura zewn\u0119trzna (1-Wire, jeden pin GPIO)<\/td>\n<\/tr>\n<tr>\n<td>MCU811<\/td>\n<td>CO2 (eCO2)<\/td>\n<\/tr>\n<tr>\n<td>INA226<\/td>\n<td>napi\u0119cie i pr\u0105d (np. zasilanie stacji)<\/td>\n<\/tr>\n<tr>\n<td>netDL 500<\/td>\n<td>poziom i temperatura wody, bateria<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Do w\u0119z\u0142a mo\u017cna te\u017c pod\u0142\u0105czy\u0107 zegar RTC DS3231, ekspander MCP23017 (16 wej\u015b\u0107\/wyj\u015b\u0107) oraz wykorzysta\u0107 wej\u015bcia analogowe GPIO.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"3_Podlaczenie_czujnikow\"><\/span>3. Pod\u0142\u0105czenie czujnik\u00f3w<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"BMEBMP280\"><\/span>BME\/BMP280<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Czujnik pod\u0142\u0105cza si\u0119 do magistrali I2C. Zasilanie (VIN) do 3,3 V. Przyk\u0142adowe piny:<\/p>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Modu\u0142<\/th>\n<th>SCL<\/th>\n<th>SDA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>TLORA T3 V1.6.1<\/td>\n<td>IO22<\/td>\n<td>IO21<\/td>\n<\/tr>\n<tr>\n<td>HELTEC V2<\/td>\n<td>IO15<\/td>\n<td>IO4<\/td>\n<\/tr>\n<tr>\n<td>HELTEC V3 \/ V4<\/td>\n<td>IO42<\/td>\n<td>IO41<\/td>\n<\/tr>\n<tr>\n<td>HELTEC E290<\/td>\n<td>IO38<\/td>\n<td>IO39<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>W modu\u0142ach TBEAM i ESP32-E2 czujnik pod\u0142\u0105cza si\u0119 do pin\u00f3w I2C wy\u015bwietlacza (przy 3,3 V pod\u0142\u0105cz VDD).<\/p>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Komenda<\/th>\n<th>Dzia\u0142anie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><code>--bme on<\/code><\/td>\n<td>w\u0142\u0105cza BME280 (lub <code>--bmp on<\/code> dla BMP280), potem restart<\/td>\n<\/tr>\n<tr>\n<td><code>--bmx off<\/code><\/td>\n<td>ca\u0142kowicie wy\u0142\u0105cza obs\u0142ug\u0119 czujnika<\/td>\n<\/tr>\n<tr>\n<td><code>--wxdebug on<\/code><\/td>\n<td>w\u0142\u0105cza dodatkowe informacje w konsoli, pomocne przy instalacji<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"1-Wire_DS18B20_DHT11\"><\/span>1-Wire (DS18B20, DHT11)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Czujniki 1-Wire pod\u0142\u0105cza si\u0119 do jednego pinu GPIO. Linia danych potrzebuje rezystora 4,7 k\u03a9 do 3,3 V.<\/p>\n<p><strong>Wa\u017cne:<\/strong> modu\u0142 DHT11 ma ju\u017c wbudowany rezystor, wi\u0119c nie dodawaj drugiego.<\/p>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Komenda<\/th>\n<th>Dzia\u0142anie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><code>--onewire gpio 4<\/code><\/td>\n<td>ustawia numer pinu GPIO (tu: 4)<\/td>\n<\/tr>\n<tr>\n<td><code>--onewire on<\/code><\/td>\n<td>w\u0142\u0105cza czujnik (<code>--onewire off<\/code> wy\u0142\u0105cza)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Przetestowane piny wed\u0142ug autor\u00f3w: TBEAM GPIO 4, T-LORA T3 V1.6.1 GPIO 4, HELTEC V2 GPIO 17, HELTEC V3.2 GPIO 7, HELTEC STICK V3 LITE GPIO 33, RAK z p\u0142ytk\u0105 13002 IO01.<\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"4_Odczyt_danych\"><\/span>4. Odczyt danych<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Warto\u015bci pomiarowe zobaczysz:<\/p>\n<ul>\n<li><strong>w konsoli szeregowej (USB)<\/strong> po komendzie <code>--wx<\/code> (lub <code>--weather<\/code>). Wy\u015bwietlane s\u0105: TEMP, TOUT, HUM, QFE, QNH, ALT asl, GAS, eCO2,<\/li>\n<li><strong>w aplikacji na smartfon<\/strong>, razem z list\u0105 aktywnych czujnik\u00f3w,<\/li>\n<li><strong>w WEBService<\/strong> w\u0119z\u0142a,<\/li>\n<li><strong>na dashboardzie APRS.fi<\/strong>, gdzie warto\u015bci trafiaj\u0105 z serwera MeshCom.<\/li>\n<\/ul>\n<p>Komendy mo\u017cna wpisa\u0107 w konsoli szeregowej lub wys\u0142a\u0107 z aplikacji jako wiadomo\u015b\u0107 tekstow\u0105. W dokumentacji spotyka si\u0119 zapis z jednym i dwoma my\u015blnikami (<code>-wx<\/code>, <code>--wx<\/code>), wi\u0119c sprawd\u017a sk\u0142adni\u0119 dla swojej wersji firmware.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"5_Stale_grupy_pomiarowe_APRSfi\"><\/span>5. Sta\u0142e grupy pomiarowe (APRS.fi)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Format telemetrii APRS pokazuje tylko 5 warto\u015bci na znak wywo\u0142awczy z SSID (np. OE1KBC-20, OE1KBC-21). Dlatego MeshCom grupuje warto\u015bci wed\u0142ug dost\u0119pnych czujnik\u00f3w:<\/p>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Grupa<\/th>\n<th>Czujniki<\/th>\n<th>Warto\u015bci w APRS.fi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\/V=1<\/td>\n<td>BME\/BMP280, 1-Wire<\/td>\n<td>Press, Temp.in, Hum, QNH, Temp.out<\/td>\n<\/tr>\n<tr>\n<td>\/V=2<\/td>\n<td>BME\/BMP280, MCU811, 1-Wire<\/td>\n<td>Press, Temp.in, Hum, eCO2, Temp.out<\/td>\n<\/tr>\n<tr>\n<td>\/V=3<\/td>\n<td>BME680, 1-Wire<\/td>\n<td>Press, Temp.in, Hum, eGAS, Temp.out<\/td>\n<\/tr>\n<tr>\n<td>\/V=4<\/td>\n<td>netDL 500, 1-Wire<\/td>\n<td>Level, Temp, Batt, Temp.out<\/td>\n<\/tr>\n<tr>\n<td>\/V=5<\/td>\n<td>INA226<\/td>\n<td>Volt, Ampere, BATT<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"6_Wlasna_grupa_pomiarowa\"><\/span>6. W\u0142asna grupa pomiarowa<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Jak_to_dziala\"><\/span>Jak to dzia\u0142a<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Od wersji firmware v4.34w04.08 mo\u017cesz samodzielnie z\u0142o\u017cy\u0107 grup\u0119 do pi\u0119ciu warto\u015bci. Ustawiasz nazwy warto\u015bci, jednostki i \u017ar\u00f3d\u0142a danych, a w\u0119ze\u0142 wysy\u0142a je w zadanym interwale.<\/p>\n<p>Dost\u0119pne \u017ar\u00f3d\u0142a (<code>-values<\/code>): <code>press<\/code>, <code>hum<\/code>, <code>temp<\/code> (BMP\/BME280, BME680), <code>onewire<\/code>, <code>co2<\/code> (MCU811), <code>gasres<\/code> (BME680), <code>batt<\/code>, <code>proz<\/code> (z sprz\u0119tu w\u0119z\u0142a), <code>vbus<\/code>, <code>vcurrent<\/code> (INA226), <code>qnh<\/code>. Warto\u015b\u0107 QNH jest wyliczana z ci\u015bnienia i zapisanej wysoko\u015bci (z GPS lub wpisanej r\u0119cznie).<\/p>\n<p><strong>Wa\u017cne:<\/strong> wiadomo\u015bci telemetryczne id\u0105 jako wiadomo\u015b\u0107 grupowa, kt\u00f3rej nie wida\u0107 na wy\u015bwietlaczu, w WEBService ani w aplikacji. Nie maj\u0105 potwierdze\u0144 (ACK), \u017ceby ograniczy\u0107 ruch, a serwer nie rozsy\u0142a ich do innych bramek. Opisy PARM, UNIT i EQNS trafiaj\u0105 do APRS.fi po starcie w\u0119z\u0142a i co 10 wiadomo\u015bci.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Ustawienie_z_wiersza_polecen\"><\/span>Ustawienie z wiersza polece\u0144<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>Komenda<\/th>\n<th>Dzia\u0142anie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><code>-parm tm1,tm2,tm3,tm4,tm5<\/code><\/td>\n<td>nazwy warto\u015bci (nieu\u017cywane pozostaw puste)<\/td>\n<\/tr>\n<tr>\n<td><code>-unit u1,u2,u3,u4,u5<\/code><\/td>\n<td>jednostki, np. V, A, mV (nieu\u017cywane pozostaw puste)<\/td>\n<\/tr>\n<tr>\n<td><code>-values v1,v2,v3,v4,v5<\/code><\/td>\n<td>\u017ar\u00f3d\u0142a danych z listy powy\u017cej<\/td>\n<\/tr>\n<tr>\n<td><code>-eqns 0,1,0, 0,1,0, ...<\/code><\/td>\n<td>opcjonalne r\u00f3wnania przeliczeniowe. Nie trzeba ich wpisywa\u0107, domy\u015blne s\u0105 ustawione<\/td>\n<\/tr>\n<tr>\n<td><code>-ptime 15<\/code><\/td>\n<td>interwa\u0142 pomiar\u00f3w w minutach<\/td>\n<\/tr>\n<tr>\n<td><code>-tel<\/code><\/td>\n<td>wy\u015bwietla zapisane ustawienia<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Przyk\u0142ad konfiguracji:<\/p>\n<pre><code>PARM: temp.in,temp.out,qfe,qnh,hum\r\nUNIT: C,C,hPa,hPa,%rel\r\nEQNS: none\r\nVALUES: temp,onewire,press,qnh,hum\r\nPTIME: 15\r\n<\/code><\/pre>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"7_Mapy_klienci_i_projekty_spolecznosci\"><\/span>7. Mapy, klienci i projekty spo\u0142eczno\u015bci<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/meshmap.oevsv.at\">MeshMap<\/a>: mapa danych z sieci (wiadomo\u015bci, pozycje, telemetria, si\u0142a sygna\u0142u, mapa cieplna temperatur). Autor: Martin DK5EN, wdro\u017cenie po stronie serwer\u00f3w: Kurt OE1KBC.<\/li>\n<li><strong>MeshCom Map (OE1KFR):<\/strong> w\u0119z\u0142y na mapie z tabel\u0105 zawieraj\u0105c\u0105 bramk\u0119, wersj\u0119 firmware, sprz\u0119t oraz temperatur\u0119, ci\u015bnienie, wilgotno\u015b\u0107 i CO2.<\/li>\n<li><a href=\"https:\/\/github.com\/DH1FR\/MeshcomWebDesk\">MeshcomWebDesk<\/a>: webowy klient (Blazor) \u0142\u0105cz\u0105cy si\u0119 z w\u0119z\u0142em przez UDP. Od v1.11.0 ma integracj\u0119 Weather API, kt\u00f3ra wprowadza dane z AWEKAS lub Weather Underground do telemetrii MeshCom.<\/li>\n<li><strong>Wiadomo\u015bci pogodowe IK5XMK:<\/strong> kod do wysy\u0142ania wiadomo\u015bci pogodowych w sieci APRS MeshCom, wymieniony na stronie klient\u00f3w open source ICSSW.<\/li>\n<\/ul>\n<p>Na stronie ICSSW wymieniono te\u017c klient\u00f3w BLE (OE3WAS, DK5EN) i UDP (DG9VH, MeshDash). Wsparcie do tych program\u00f3w zapewniaj\u0105 ich autorzy.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Zrodla\"><\/span>\u0179r\u00f3d\u0142a<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"https:\/\/icssw.org\/en\/telemetrie-dynamisch-konfigurieren\/\">Telemetria i zdalne prze\u0142\u0105czanie (ICSSW)<\/a><\/li>\n<li><a href=\"https:\/\/icssw.org\/en\/telemetrie-dynamisch-zusammenstellen\/\">Dynamiczne zestawianie telemetrii (ICSSW)<\/a><\/li>\n<li><a href=\"https:\/\/icssw.org\/en\/bmp-bme280-sensor\/\">Czujnik BMP\/BME280 (ICSSW)<\/a><\/li>\n<li><a href=\"https:\/\/icssw.org\/en\/onewire-temperatur-sensor\/\">Czujnik 1-Wire (ICSSW)<\/a><\/li>\n<li><a href=\"https:\/\/icssw.org\/en\/opensource-meshcom-clients\/\">Klienci open source (ICSSW)<\/a><\/li>\n<li><a href=\"https:\/\/meshcom.pl\/?page_id=687\">Wysy\u0142anie pozycji w MeshCom (MeshCom Polska)<\/a><\/li>\n<li><a href=\"https:\/\/github.com\/icssw-org\/MeshCom-Firmware\">Firmware MeshCom na GitHubie<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>1. Jak dzia\u0142a telemetria W\u0119ze\u0142 MeshCom z pod\u0142\u0105czonym czujnikiem wysy\u0142a dane pomiarowe jako osobny rodzaj wiadomo\u015bci (telemetria) na cz\u0119stotliwo\u015bci MeshCom, domy\u015blnie 433,175 MHz. Gdy dane dotr\u0105 do serwera MeshCom, s\u0105 przekazywane do dashboardu APRS.fi w formacie telemetrii APRS. Dane pogodowe s\u0105 te\u017c wysy\u0142ane razem z pozycj\u0105 w\u0119z\u0142a (co 30 minut), je\u015bli czujnik jest pod\u0142\u0105czony. Szczeg\u00f3\u0142y: [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-751","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/pages\/751","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/meshcom.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=751"}],"version-history":[{"count":4,"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/pages\/751\/revisions"}],"predecessor-version":[{"id":757,"href":"https:\/\/meshcom.pl\/index.php?rest_route=\/wp\/v2\/pages\/751\/revisions\/757"}],"wp:attachment":[{"href":"https:\/\/meshcom.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=751"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}